Add to Cart
Irrigation water flow meter by magnetic flow meter, in agriculture, waste water, grey water flow monitoring
Communication and analoge output:
Our electromagnetic flow meter includes both 4-20mA and pulse output. Communication option: Modbus RS485, GPRS, Bacnet, NB-iot. The transmitter can be mounted either integrally to the flow sensor or remotely. The transmitter features a three-line LCD that displays the flow total, flow velocity, flow rate percent of range, and alarm settings. A four-button keypad is used to change settings. There are 27 flow unit options to choose from programmed into the transmitter. .
Applications:
Irrigation, clean water, paper pulp, slurry, sewage, waste water, HVAC/R system monitoring, residential water meter, industrial & commercial water utilities.
Standard features
Flow transmitter type | Remote or compact |
Pipe diameter | DN15 mm - DN3000 mm |
Power supply | AC85-230V / DC 8-36V / Battery / PV |
Accuracy | 0.5% |
Power consumption | < 6W |
Protection | IP68 (flow sensor) |
Media temperature | Hard rubber: -20 C - 70 C PTFE: -20C - 120 C |
Environment temperature | -20 to 50 C |
Explosion proof | EXID |
Flow direction | forward and reverse |
Communication | Modbus RS485 / Bacnet / GPRS / NT-Iot / Lora |
Signal output | 4-20 mA, pulse, frequency |
Technical data:
1. Diameter: DN15 - DN1200
2. Pressure rating: PN10/PN16/PN25/PN40
3. Media temperature: 0-80 C (Rubber), 0-120 C (PTFE)
4. Environment temperature: 0 - 60 C
5. Protection: IP68 (flow sensor)
6. Explosion proof: EXID
Parameters
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |